Trip a generator and watch the grid catch itself. Inertia sets how fast frequency falls; a battery's speed is what stops it short of the lights going out.

Grid frequency is the tachometer of the whole system: 50 Hz means generation and demand match. Lose a big infeed and frequency falls — and how fast it falls in the first instant is set by inertia, the kinetic energy stored in spinning synchronous plant. The swing equation makes it concrete: RoCoF ≈ loss ÷ inertia. Swap synchronous plant for inverter-based wind, solar and batteries and that inertia drops — GB's operating floor fell to 120 GVA·s in 2024, from roughly 300 a decade earlier — so the same trip falls faster and deeper.

A battery earns its money by being fast. Dynamic Containment, a post-fault service that ramps to full output by ±0.5 Hz within a second, arrests the fall and lifts the nadir. Grid-forming units go further: as voltage sources they give an inertia-like response that flattens the initial slope itself — the part fast response can't reach. Different products for different moments of the fall.

This is a single-bus teaching model — one uniform system frequency, no locational effects — with illustrative parameters you can move, not a validated study of any real grid. It settles off-nominal, at a droop offset; full restoration to 50 Hz is secondary response over minutes, off-screen. Grid-forming inertia saturates at the inverter's current limit, unlike true spinning mass. And load damping — modelled here — is itself fading as demand becomes power-electronic, the same story as inertia. One simplification to know: load that is shed stays off for the 30 seconds shown, and damping uses demand as it was before shedding.

The revenue is real. NESO's three Dynamic services are all here. Dynamic Regulation and Dynamic Moderation are pre-fault — they reach full output by ±0.2 Hz, DR slowly (10 s) and DM fast (1 s) — so in a large fall they saturate early and DR barely delivers before the nadir. Dynamic Containment is the post-fault service: it alone keeps responding past ±0.2 Hz, to full output at ±0.5 Hz — which is why containment-scale volume is what holds a deep event. Grid-forming is separate again: it's synthetic inertia, not a frequency-response service. NESO procures the Dynamic trio for response and, separately, inertia and stability through the Long-Term 2029 tender, successor to the Stability Pathfinders. Grid-forming itself was codified in GB's Grid Code (GC0137, a 2022 world-first) and is growing, though still a minority of contracted inertia today. Note the toy models demand disconnection below 48.8 Hz (UFLS), which is a different mechanism from RoCoF loss-of-mains protection.